Type NGTT, RGTT & C1 (M) NGT (M) are specially designed for motor protection application. They are suitable for both Direction-line motor starting application and in conjunction with contractors for star/Delta motor starting. These fuses offer protection for the motor circuit from inadmissible high over current and in case of short circuit, isolation takes place at the fastest give time. The fuses are designed to withstand surges due to frequent Starting of the motors.


Square & Din type Fuse Series

Square & Din type Fuse Series

ESWARI's Semiconductor fuse-links provide maximum flexibility in equipment design and ultimate protection for today's power conversion equipment. These square body fuse-links are available in four different body sizes, each size having seven word wide acceptable mounting styles. The different mounting styles and body sizes long with a broad range a ampere ratings allow greatest flexibility in flexibility in equipment design.

 

Features:

 

  • Choice of mounting styles give wire choice for equipment disign.

  • Broad range of eampere ratings in given body size for design flexibility.

  • IEC 269-4 compliance for worldwide semiconductor applications.

  • Extremely Fast Acting and Current LImiting.

  • Very LOw 12t. and Worldwide Acceptability.

  • Superior cycling Ability.


Applications:

 

Protection of rectifiers, inverters, DC drives, UPS reduced voltage motor starters, and other equipment.




British Standard Fuse Series

ESWARI's BS range of fuse links are designed]

to the requirements of IEC269-IV(1986).

Precise Pre-determined performance ensuring low

are voltage and minimum let through of current

and energy. Exceptionally compact deminsions

available in a wide range of current and voltage

ratings

 

Features


  • 1. Extremely high interrupting rating fuses
  • 2 Protection of power semiconductors according to IEC 269.1 and 4

Applications


Protection of rectifiers,inverters,DC drives,UPS

Systems,reduced voltage motor starters, and other

equipment


British Standard Fuse Series



Cylidrical Fuse Series

Cylidrical Fuse Series

ESWARI's cylindrical fuses features various ratings required by the industries for protecting semiconductors. Cylindrical fuses also have the lowest l2t of all similar fusesand excellent cycling ability.

 

Features :

  • Extremely high interrupting rating fuses

  • Protection of power semiconductors

    according to IEC 269.1 and 4


Applications:-

Applications include inverters ans small equipment requiring extremely fast response to faults,without the need to carry sustained heavy overloads.




C-1 Series

Type

 

Rated Voltage Kv Un

Rated Current A In

 

Catalogue No

Max. Power Dissipation (Watts)

Rated Breaking Capacity kA

Weight / unit in Kg

C1 W

3.3 / 3.6

6.6 / 7.2

6.3

10

16

20

25

31.5

40

50

63

C1 W6

C1 W10

C1 W16

C1 W20

C1 W25

C1 W32

C1 W40

C1 W50

C1 W63

3

4

5

6

8

10

16

18

25





40

 





2.5




C1 WA

3.3 / 3.6

6.6 / 7.2

 

80

100

125

160

200

250

315

C1 WA80

C1 WA100

C1 WA125

C1 WA160

C1 WA200

C1 WA250

C1 WA315

29

36

44

50

55

63

89




40

 




3.5

 


C-1 Series



Fuse Cutouts

Fuse Cutouts

ESWARI'S EXPULSION CUTOUT-NGTK provides safe, reliable overcurrent protection toe the industries applications. The NGTK cutouts design will give perfect protection for the industrial equipements from system overloads and under other fault conditions.

 

Salient Features:


  • Resistance to ageing

  • U.V Retardant

  • Very High Dielectric Strengt

  • Protection of ingress of moisture

  • Application Flexibility

  • Trouble free operation

  • Outstanding performance


Applications :


Eswari'S Expulsion Fuse Cutouts (DDLO) which fused with Eswari's fuse links provides a wide range of protection for over head distribution systems rated from 10 kV to 36 kV. Eswan'S Expulsion Fuse Cutouts (DDLO) will interrupt all fault from the lowest current that will melt the fuse links to the maximum rated breaking current. Eswari'S Expulsion Fuse Cutout will accommodate standard or removable button head type fuse links from 1 A to 200 A. The selection of appropriate fuse links depends on type and rating for particular application as a function of Load Current, type of equipment and the required co-ordination with other over current protective equipment.


Ratings:


  • The Rating of the Eswari'S Expulsion Fuse Cutouts (DDLO) is expressed in terms of voltage & current rating.

  • Standard voltage rating are maintained between 11/12 kV, 22/24 kV and 33/36 kV.

  • The fuse cutouts are capable of carries a carries a maximum current of 100A and 200A.


Standards & Design Testing:


  • IS - 9385-2

  • IEC 60282-2

  • NEMA SG-2-1986

  • ANSI C37.41.1994

  • ANSI C37.42-1989




NGT M Series

Type

Rated Voltage kV Un

Rated Current A In

Catalogue No.

Dimensions in mm

Max. Power Dissipation (Watts)

Rated Breaking Capacity kA L1

Weight/unit in Kg

NGTWM

3.3/3.6

6.6/7.2

50

63

80

100

NGTWM50

NGTWM63

NGTWM80

NGTWM100

 

 

292

 

 

63.5

25

35

45

52

 

 

2

NGTWAM

3.3/3.6

6.6/7.2

125

160

200

NGTWAM125

NGTWAM160

NGTWAM200

 

 

292

 

 

85

62

79

97

 

4

NGTWBM

3.3/3.6

6.6/7.2

250

300

NGTWBM250

NGTWBM300

 

442

 

85

125

135

 

6

NGTXM

11/12/11

50

63

NGTXM50

NGTXM63

 

292

 

63.5

49

67

 

2

NGTXAM

11/12

 

80

100

125

NGTXAM80

NGTXAM100

NGTXAM125

 

292

 

85

76

89

95

 

4

 

NGTXBM

11/12

 

160

200

NGTXBM160

NGTXBM200

 

442

 

85

103

128

 

6


NGT M Series



C-1 M Series

C-1 M Series

Type

Rated Voltage kV Un

Rated Current A In

Catalogue No.

Max. Power Dissipation (Watts)

Rated Breaking Capacity kA L1

Weight/unit in Kg

C1WM

3.6/7.2

50

63

C1WM50

C1WM63

18

25

 

40

 

2.5

C1WAM

 

3.6/7.2

 

 

80

100

125

160

200

250

315

C1WM50

C1WM100

C1WM125

C1WM160

C1WM200

C1WM250

C1WM315

39

36

44

50

55

63

89

 

 

40

 

 

 

3.5




Exp Cutout NGT-K Procelain Series

We are engaged in offering a superior range of Exp Cutout NGT-K Porcelain Series to our clients. These are sourced from trusted vendors in the market. Our range provides perfect protection for the industrial equipment against system overloads. It also protects the equipment under any other faulty conditions. These are available in various specifications that meet the individual requirement of clients. Our products are highly appreciated for trouble free operations, outstanding performance and very high dielectric strength features.


Exp Cutout NGT-K Procelain Series




Hookstick

Hookstick


Eswari's Hook Stick is first attached to a universal pole atleast six feet feet long. it is then positioned across the front of the NGT K Cutout, with the Hook Stick anchor hung on the attachment hook on the far side of the cutout. The pull ring of the fuse tube or disconnect blade is engaged with Hook Stick’s pull-ring hook and held fast with Hook Stick’s pull-ring latch. As the universal pole is pulled downward with firm, steady stroke, and as Hook Stick is extended to its maximum length, the cutout is opened and the current is diverted through Hook Stick-at the same time Hook Stick’s opening stroke, its internal trigger trips, the charged operating spring is released, the internal contact are separated, and the circuit is positively interrupted.




Exp Cutout NGT-KA Procelain Series

We also offer Exp Cutout in NGT-KA Porcelain Series to our clients at market leading prices. The exclusive range of Exp Cutout NGT-KA Porcelain Series provides complete protection to the electric equipment from any erroneous conditions. Further, it is widely used as protection overhead distribution systems in distribution transformers. These products find wide application in various industries such as oil, engineering and sugar industries. We also make sure that our range is free from any defects and ideal for use in different applications.


Exp Cutout NGT-KA Procelain Series




Exp Cutout NGT-KP Procelain Series

Exp Cutout NGT-KP Procelain Series


Our organization specializes in providing premium quality Expulsion Fuse in Exp Cutout NGT-KP Porcelain Series, which are procured from reliable vendors in the market. These fuses are specially designed to offer complete protection solutions against system overloads and short circuit fault currents. Our range finds huge demand in the competitive market for the excellent performance, is safe to use and easy to install. Moreover, we are capable of meeting the bulk order of our clients within a stipulated time frame.


Note: For more information, please refer attached PDF.





VT Protection Fuses

The instrument transformers fuse-links are used to protect switchgear equipment against short-circuits in indoor voltage transformers. Protection of switchgear equipment is very effective thanks to unlimited breaking capacity and short circuit current limitation. Thanks to very small dimensions WBP type fuse-links can be used in various types of switchgear, including flame-proof types.





VT Protection Fuses



North American And Round Body Type Fuses

North American And Round Body Type Fuses

Eswari's Semiconductor protection fuses are

designed for the protection of diodes and other

semiconductor devices. It provides a compact

design for those applications that have limitations

on available space.

 

Features:

 

  • Low l2t minimizes damage to protected

    components on short circuit

  • Controlled are voltage reduces stress to

    circuit components during fuse clearing

  • Choice of mounting type provides options

  • for unique termination requirements

 

Applications:

Protection of AC/DC drives, UPS,Rectifiers




C-O Series Fuses

WE offer wide range of  C-O Series.

Refer attavhed pdf for more details.



C-O Series Fuses



C-1 Series.

C-1 Series.

We offer wide range of C-1 Series.

Refer attached pdf for more details.




BHT Series

Fuse Protection for Oil insulated Switchgear




Fuse Selection Table

Starting Time

No. of starts/hour

Maximum permissible starting current in Amps

5 Sec

2

4

8

16

740

675

615

550

480

440

400

360

360

330

300

275

250

230

210

190

130

120

110

100

90

80

75

65

15 Sec

2

4

8

16

635

580

530

475

430

400

360

325

325

285

260

225

225

200

180

160

120

110

100

90

85

75

70

60

30 Sec

2

4

8

16

600

530

460

400

420

370

320

250

300

260

230

200

210

180

160

140

120

100

90

80

80

70

65

55

Fuse Rating in Amps

 

15

200

160

125

80

50



Motor Protection Fuses

Type NGTT, RGTT & C1 (M) NGT (M) are specially designed for motor protection application. They are suitable for both Direction-line motor starting application and in conjunction with contractors for star/Delta motor starting. These fuses offer protection for the motor circuit from inadmissible high over current and in case of short circuit, isolation takes place at the fastest give time. The fuses are designed to withstand surges due to frequent Starting of the motors.



Dimension Table Of Fuses

All Dimensions are in mm:

 

Type

A

B

C

D

E

F

C1W

346

245

308

63.5

57

36.5

C1WA

360

254

310

85

63

43.5

 

Fuse Selection Table


Capacitor rated capacity in KVAR

Line Voltage in kV

3.3 / 3.6

6.6 / 7.2kV

11 / 12 kV


Rated current of the Fuse Link (A)


50

75

100

125

160

200

250

315

400

500

630

800

1000

1250

16

24

32

40

51

64

80

102

128

160

200

250

315

400

8

12

16

20

26

32

40

50

64

80

100

128

160

200

6.3

8

10

12

16

20

25

31.5

40

50

63

80

100

120








Contact Us

Mr. Sunil Luthra (Ceo)
4/116, Subhash Nagar
New Delhi, Delhi - 110 027, India
Telephone:+(91)-(11)-25135842/ 25140159



Home  |  About Us  |  Our Product Range  |  Media Gallery   |  Site Map  |  Contact Us   |  Enquiry

Member IndiaMART.com © Hydro Electricals. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Business Enquiry Form


Add More Products / Services

(* represents compulsory fields )

*Describe Your Requirements in Detail
Please Fill Your Contact Information
*Contact Person:
*Email:
Company:
Street Address:
*Country:
*Telephone:
Mobile:
Website:
*Enter the code:

Send me a copy of this enquiry